⚡ 14923 RUFUS WILSON RD

Washington, MD — Intake Report
📍 39.6552567, -77.8522634 📐 13.3 acres 🏷️ APN: 23003783 🔌 39a55b46-fd6d-4ef4-abe2-7e18a192b596 📅 Generated May 12, 2026 12:31 PM 🆔 MD004652
Go
BESS Score: /10 Buildable: ac Nearest Sub: Wilson Conococheague (0.1 mi) Zoning: Residential - Rural/Agricultural Residence
🗺️ Map
📐 Site Layout
📋 Overview
🤖 AI Analysis
📝 Notes

🔍 Site Diligence

Complete these items. Changes save automatically.
AHJ Confirmed
Verify governing jurisdiction via municipality overlay
Zoning Verified
Confirm BESS-compatible zoning or CUP/SUP pathway
Flood/Wetlands Clear
FEMA Zone X or buildable area avoids flood/wetlands
Site Access Confirmed
Road access, easements, equipment delivery route
Substation Feasibility
Nearest substation capacity and voltage suitable
Setback Analysis
Buildable acreage accounts for required setbacks
Environmental Clear
No endangered species, conservation areas, brownfield issues
Title Clear
No liens, encumbrances, or easement conflicts

📝 Diligence Fields

🏠 Property Details

BOWERS DONALD PAUL
13.3
23003783
Residential - Rural/Agricultural Residence (U)
Battery Energy Storage
Washington
24043
13.44 ACRES 14923 RUFUS WILSON ROAD 14921 RUFUS WILSON ROAD

⚡ Infrastructure

39a55b46-fd6d-4ef4-abe2-7e18a192b596
Wilson Conococheague
0.1 mi
-999999 kV
138kV at 3.1 mi (THE POTOMAC EDISON COMPANY)
Public
POI Onsite
Good

🌊 Environmental

Loading...
Loading...
No
None within ~3 miles
None within ~2 miles
None
None
None within ~2 miles

💰 IRA/ITC Adders

No
Yes — Coal Closure
No

🏛️ Jurisdiction

Loading from layers...

📊 Assessment

Go
/10

🤖 AI Site Assessment — Gemini Deep Research

Site Diligence Analysis: 14923 RUFUS WILSON RD, Washington County, MD

As a senior BESS site evaluation analyst for Sunland America Corp, I have performed a comprehensive diligence analysis for the property located at 14923 RUFUS WILSON RD in Washington County, Maryland. This analysis focuses on the suitability of the 13.3-acre parcel for a distribution-scale (≤5MW) or potentially a smaller utility-scale Battery Energy Storage System project.

1. Site Access & Topography

  • Road Access Quality and Equipment Delivery Feasibility: The property benefits from "Public" road access via Rufus Wilson Rd. While the specific quality of Rufus Wilson Rd (e.g., paved width, load bearing capacity) is unknown, public access generally implies a reasonable standard for standard vehicle traffic. For heavy equipment delivery, such as large transformers, battery containers, and construction machinery, a detailed assessment of the road's condition, turning radii at intersections, and any potential overhead obstructions (e.g., utility lines, low bridges) will be required. Given the "Residential - Rural/Agricultural Residence" zoning, it is likely a rural road, which may necessitate upgrades or specific routing plans for oversized loads.
  • Likely Terrain Characteristics: The property's location in an unincorporated, rural/agricultural area of Washington County, combined with a "Good" buildability assessment, suggests that the terrain is likely flat to gently rolling. This is highly favorable for BESS construction, minimizing the need for extensive grading and earthwork, which can significantly reduce civil costs and construction timelines.
  • Heavy Equipment Access: With "Public" road access and the "POI Onsite" (Point of Interconnection), direct access for heavy equipment appears feasible, assuming the road quality can support the loads. The "Good" buildability rating further supports the expectation that the site itself is amenable to heavy machinery movement and pad construction.
  • Access Easement Concerns: No specific access easement concerns are noted in the provided data. However, for any project requiring significant road improvements or utility line extensions, securing necessary easements from adjacent landowners or the county would be a standard due diligence item.

2. Environmental Constraints

  • FEMA Flood Zone Designation: The FEMA Flood Zone designation is Unknown. This is a critical data gap. A BESS cannot be sited within a 100-year flood plain (Zone AE, A, or V) without significant, costly, and often unfeasible mitigation measures (e.g., elevated platforms). Immediate verification of the FEMA flood map for this APN (23003783) is required.
  • Wetlands Presence and Setback Requirements: The presence of wetlands is also Unknown. Wetlands can severely restrict developable area and trigger complex, lengthy, and expensive permitting processes (e.g., US Army Corps of Engineers Section 404 permits, state-level permits). A wetland delineation study will be necessary to identify any jurisdictional wetlands and determine applicable setback requirements, which can range from 25 to 100 feet or more depending on wetland classification and local regulations.
  • Critical Habitat / Endangered Species Risk: The data indicates "None" for critical habitat. This is a positive finding, as it avoids potential project delays, costly mitigation, and federal/state permitting complexities associated with the Endangered Species Act.
  • Brownfield/Superfund Status: The property is "None within ~2 miles" of a Brownfield/Superfund site. This is favorable as it eliminates environmental remediation risks and associated liabilities. However, it also means the project will not qualify for the IRA Brownfield ITC bonus adder.
  • Chesapeake Bay Critical Area Implications: The property is "No" within the Chesapeake Bay Critical Area. This is a significant advantage, as it avoids the stringent development restrictions, impervious surface limits, and enhanced environmental review processes mandated for projects within this sensitive watershed area in Maryland.
  • Pipeline Proximity Safety Considerations: There are "None within ~3 miles" of pipelines. This is excellent, as it eliminates major safety concerns, potential blast zones, and restrictive setback requirements often imposed around high-pressure gas or hazardous liquid pipelines, which can severely limit developable area and increase project risk.

3. Grid Infrastructure & Interconnection

  • Nearest Substation: The "Wilson Conococheague" substation is exceptionally close, at a distance of only 0.1 miles. The "Max Voltage: -999999 kV" is clearly a data error; however, the proximity strongly suggests a distribution substation. This is an extremely favorable condition for interconnection.
  • Nearest Transmission Line: A 138kV transmission line owned by THE POTOMAC EDISON COMPANY is located 3.1 miles away. While present, the direct proximity to a substation makes a transmission-level interconnection less likely for a distribution-scale BESS.
  • Likely Interconnection Voltage: Given the 0.1-mile distance to the Wilson Conococheague substation and the "POI Onsite" indication, the most likely and cost-effective interconnection voltage will be at the distribution level (e.g., 12.47kV, 34.5kV) directly into the substation or an adjacent feeder. This avoids the complexity and higher costs associated with transmission-level interconnections. The Interconnecting Utility is Potomac Edison (a FirstEnergy company).
  • Estimated Interconnection Cost Range and Timeline: With the POI onsite and such close proximity to a substation, the interconnection costs for a distribution-level project could be relatively low, potentially in the range of $500,000 to $1.5 million, primarily for substation upgrades, protection schemes, and minimal line extension. However, this is highly dependent on available capacity at the substation. The timeline for a distribution-level interconnection with Potomac Edison (FirstEnergy) in Maryland typically ranges from 18-36 months, including study phases (Feasibility, System Impact, Facilities) and construction.
  • Utility-Specific IX Process and Typical Queue Times: Potomac Edison, as part of FirstEnergy, follows a structured interconnection process. For projects under 20 MW in Maryland, this typically involves a state-level process managed by the utility, often mirroring PJM's smaller generator interconnection procedures. Queue times can vary significantly based on the number of active projects and available capacity. A pre-application meeting with Potomac Edison is highly recommended to assess substation capacity and potential upgrade requirements early.
  • Likely Feeder Configuration: The "POI Onsite" and extreme proximity to the substation suggest the site is likely located directly on a robust distribution feeder emanating from the Wilson Conococheague substation, or has direct access to the substation bus. This is ideal for minimizing new line construction and maximizing reliability.

4. Regulatory & Zoning Analysis

  • Authority Having Jurisdiction (AHJ) and its Type: The AHJ is Washington County, MD, as the property is located in an unincorporated area. This means county-level planning, zoning, and permitting departments will govern the project.
  • Current Zoning for BESS Compatibility: The current zoning is "Residential - Rural/Agricultural Residence (Code: U)" and "A(R" (Regrid). This is a significant red flag. BESS facilities are typically classified as industrial or utility uses. Siting an industrial-type facility in a residential/rural/agricultural zone is highly problematic and represents the primary regulatory hurdle for this site.
  • Recommended Permitting Pathway: A "by-right" approval is extremely unlikely given the zoning. The most probable pathways would be a Conditional Use Permit (CUP) or a Special Exception. These processes require extensive review by the county planning commission, often involve public hearings, and necessitate demonstrating that the project will not adversely impact the surrounding community (e.g., noise, visual impact, traffic, safety). Rezoning to an industrial or utility zone is another, more difficult and time-consuming, option. A variance is generally for minor deviations from zoning requirements, not for a primary use that is fundamentally incompatible.
  • Known Setback Requirements: Specific setback requirements for BESS in Washington County, MD, are Unknown and would need to be researched in the county's zoning ordinance. However, for industrial uses in residential/rural zones, significant setbacks (e.g., 50-200 feet from property lines and residential structures) are common to mitigate noise and visual impacts.
  • Reference Specific State/County Regulations: Maryland has state-level regulations for BESS, including fire codes (e.g., NFPA 855) and potentially siting guidelines. Washington County's zoning ordinance will dictate local land use requirements.
  • Moratorium or Restriction Risks: Given the residential/rural zoning, there is a high risk of local opposition (NIMBYism - Not In My Backyard) and potential for the county to impose a moratorium or strict restrictions on BESS development in such zones, especially if they have not yet developed specific BESS ordinances. This risk needs to be proactively managed through community engagement.

5. IRA/ITC Incentive Analysis

  • Opportunity Zone Eligibility: The property is "No" in an Opportunity Zone, meaning it will not qualify for the additional ITC bonus for Opportunity Zone investments.
  • Energy Community Status: The property is

📸 Satellite Inspection

Satellite Close-up
Close-up (Zoom 17)
Satellite Wide
Context View (Zoom 14)
Terrain Map
Terrain / Roads

📝 Add Note

📋 Note History

No notes yet. Add the first note above.