⚡ 4 BOSTON RD

Hampden County, MA — Intake Report
📍 42.1461618, -72.2818086 📐 21.67 acres 🏷️ APN: 227 3_6_1 🔌 38cc5e9a-3437-4974-ba4f-eb0a6dceb1f6 📅 Generated July 01, 2026 02:34 PM 🆔 MA006399
BESS Score: /10 Buildable: ac Nearest Sub: Palmer (1 mi) Zoning: Industrial (General) - Industrial (General)
🗺️ Map
📐 Site Layout
📋 Overview
🤖 AI Analysis
📝 Notes

🔍 Site Diligence

Complete these items. Changes save automatically.
AHJ Confirmed
Verify governing jurisdiction via municipality overlay
Zoning Verified
Confirm BESS-compatible zoning or CUP/SUP pathway
Flood/Wetlands Clear
FEMA Zone X or buildable area avoids flood/wetlands
Site Access Confirmed
Road access, easements, equipment delivery route
Substation Feasibility
Nearest substation capacity and voltage suitable
Setback Analysis
Buildable acreage accounts for required setbacks
Environmental Clear
No endangered species, conservation areas, brownfield issues
Title Clear
No liens, encumbrances, or easement conflicts

📝 Diligence Fields

🏠 Property Details

BRETON REALTY LLC
21.67
227 3_6_1
Industrial (General) - Industrial (General) (RR)
Battery Energy Storage
Hampden County
25013
-

⚡ Infrastructure

38cc5e9a-3437-4974-ba4f-eb0a6dceb1f6
Palmer
1 mi
115 kV kV
115kV at 0.6 mi (FITCHBURG GAS AND ELECTRIC LIGHT COMPANY)
442 ft
Farmland of statewide importance
🔴 131 structures within 0.5 mi (setback/opposition risk)
Public
POI Onsite
Good

🌊 Environmental

Loading...
Loading...
N/A (non-MD)
None within ~3 miles
None within ~2 miles
None
None
1 site(s) within ~2 mi

💰 IRA/ITC Adders

No
No
No

🏛️ Jurisdiction

Palmer
City
Palmer Town

📊 Assessment

/10

🤖 AI Site Assessment — Gemini Deep Research

1. Site Access & Topography

Road Access & Feasibility: The property has direct frontage on Boston Road (US Route 20), a major public thoroughfare. This provides excellent and unrestricted access for all phases of development, from initial surveying to final equipment delivery. Based on aerial imagery, Boston Road appears to be a well-maintained, multi-lane road capable of handling oversized and overweight loads typical for BESS construction, such as transport trucks carrying battery containers, medium-voltage transformers, and mobile cranes. No obvious obstructions like low bridges or tight turns are apparent leading to the site.

Terrain & Buildability: The parcel is located in an area with generally flat to gently rolling topography. The "Good" buildability rating is consistent with aerial views, which show the site as largely cleared and level, having been previously used for industrial or commercial purposes. This is highly advantageous, as it will likely minimize the need for extensive civil work, grading, and earthmoving, thereby reducing site preparation costs and timelines. The ground appears stable and suitable for the concrete pads required for BESS equipment.

Heavy Equipment Access: Given the direct access from US-20 and the flat, open nature of the site, there are no foreseeable challenges for accessing the property with heavy equipment. Cranes for lifting and placing battery enclosures and transformers will have ample room to maneuver. A preliminary logistics plan should confirm specific laydown areas and crane placement, but initial assessment is highly positive.

Easement Concerns: The data indicates "POI Onsite," which strongly suggests a pre-existing utility easement crosses the property. This is a significant benefit for interconnection but must be precisely located. A full title search and an ALTA survey are mandatory to identify the exact location, width, and restrictions of this and any other easements (e.g., access, drainage) that could impact the final site layout and buildable area.

2. Environmental Constraints

FEMA Flood Zone: The FEMA flood zone designation is listed as "Unknown." This represents a critical information gap and a potential fatal flaw. Development within a Special Flood Hazard Area (SFHA) would trigger significant design constraints, including elevating all equipment above the Base Flood Elevation (BFE), and may face permitting challenges. Immediate verification using the FEMA Flood Map Service Center is required.

Wetlands: The presence of wetlands is "Unknown." Massachusetts has stringent wetland protection regulations under the Massachusetts Wetlands Protection Act. The presence of jurisdictional wetlands would necessitate significant setbacks (typically 100-foot buffer zones) that could severely constrain the buildable envelope. A desktop screening using MassGIS and the National Wetlands Inventory (NWI) is the first step, likely to be followed by a formal wetland delineation by a certified professional.

Critical Habitat / Endangered Species: The data indicates no critical habitat on site, which is a positive initial finding. However, as standard practice, a query of the USFWS IPaC (Information for Planning and Consultation) system and the Massachusetts Natural Heritage & Endangered Species Program (NHESP) database should be conducted to screen for any threatened or endangered species that may have habitats in the vicinity.

Brownfield/Superfund Status: The presence of a Brownfield/Superfund site within two miles is noted. This does not automatically qualify our parcel. However, given the site's industrial zoning and history, there is a possibility it could qualify as a brownfield site itself. This presents both a risk (potential contamination requiring remediation) and an opportunity (eligibility for the 10% Brownfield ITC adder). A Phase I Environmental Site Assessment (ESA) is essential to determine the site's status. If it qualifies, the 10% adder could significantly improve project economics.

Pipeline Proximity: The absence of major gas pipelines within a three-mile radius is a significant safety and permitting advantage, eliminating risks associated with pipeline-related setbacks and explosion hazards.

3. Grid Infrastructure & Interconnection

Substation & Transmission Proximity: The site's grid access is its most compelling feature. It is located just 1 mile from the Palmer Substation (115 kV class) and 0.6 miles from a 115 kV transmission line. This close proximity to robust grid infrastructure is ideal for a BESS project, minimizing the length and cost of a potential tie-line.

Point of Interconnection (POI): The claim of "POI Onsite" is a potential game-changer but requires urgent verification. If a suitable distribution feeder (e.g., 13.8 kV or 23 kV) from the

📸 Satellite Inspection

Satellite Close-up
Close-up (Zoom 17)
Satellite Wide
Context View (Zoom 14)
Terrain Map
Terrain / Roads

📝 Add Note

📋 Note History

No notes yet. Add the first note above.