⚡ 1480 RENAISSANCE DR

Cook County, IL — Intake Report
📍 42.0336601, -87.8646427 📐 35.02 acres 🏷️ APN: 9221100050000 🔌 6fb54528-966c-4764-bda6-1e20dc045eb5 📅 Generated July 06, 2026 05:13 AM 🆔 IL001590
BESS Score: /10 Buildable: ac Nearest Sub: - (-) Zoning: Commercial (Office) - Office Bldg (Multi-Story)
🗺️ Map
📐 Site Layout
📋 Overview
🤖 AI Analysis
📝 Notes

🔍 Site Diligence

Complete these items. Changes save automatically.
AHJ Confirmed
Verify governing jurisdiction via municipality overlay
Zoning Verified
Confirm BESS-compatible zoning or CUP/SUP pathway
Flood/Wetlands Clear
FEMA Zone X or buildable area avoids flood/wetlands
Site Access Confirmed
Road access, easements, equipment delivery route
Substation Feasibility
Nearest substation capacity and voltage suitable
Setback Analysis
Buildable acreage accounts for required setbacks
Environmental Clear
No endangered species, conservation areas, brownfield issues
Title Clear
No liens, encumbrances, or easement conflicts

📝 Diligence Fields

🏠 Property Details

IMPERIAL REALTY CO -
35.02
9221100050000
Commercial (Office) - Office Bldg (Multi-Story) (-)
Battery Energy Storage
Cook County
17031

⚡ Infrastructure

6fb54528-966c-4764-bda6-1e20dc045eb5
-
-
- kV
138kV at 1.5 mi (COMMONWEALTH EDISON CO)
633 ft
Not prime farmland
🔴 941 structures within 0.5 mi (setback/opposition risk)
Public

🌊 Environmental

Loading...
Loading...
N/A (non-MD)
None within ~3 miles
None within ~2 miles
None
None
1 site(s) within ~2 mi

💰 IRA/ITC Adders

No
Yes — Fossil Fuel Employment (FFE Area)
No

🏛️ Jurisdiction

Park Ridge
City
Park Ridge

📊 Assessment

/10

🤖 AI Site Assessment — Gemini Deep Research

MEMORANDUM

TO: Sunland America Corp. Development Team

FROM: Senior BESS Site Evaluation Analyst

DATE: October 26, 2023

SUBJECT: Comprehensive Site Diligence Analysis for "Project Ridge"

PROPERTY: 1480 RENAISSANCE DR, PARK RIDGE, COOK COUNTY, IL (APN: 09221100050000)


This report provides a comprehensive due diligence analysis for the potential acquisition and development of a distribution-scale Battery Energy Storage System (BESS) at the subject property. The analysis identifies critical path items, potential risks, and recommended next steps to determine project viability.

1. Site Access & Topography

Road Access & Delivery Feasibility: The site benefits from excellent road access. It is located in a modern corporate office park just off the I-294 (Tri-State Tollway), a major regional highway. The designated "Public" road access is via Renaissance Drive, a wide, paved, multi-lane road designed to handle commercial truck traffic. This infrastructure is highly conducive to the delivery of oversized and overweight equipment, including battery containers, power conversion systems (PCS), and main power transformers.

Terrain Characteristics: The property is situated in the greater Chicago metropolitan area, a region known for its exceptionally flat topography. On-site terrain is expected to be flat to gently sloping, which is ideal for BESS development as it will significantly minimize civil engineering and grading costs. A formal topographic survey will be required to confirm precise elevations.

Heavy Equipment Access: Access for construction equipment, such as large cranes required for setting transformers and switchgear, appears to be straightforward. There are no obvious vertical clearance restrictions (e.g., low bridges) or challenging turning radii on the approach to the site.

Easement Concerns: As part of a developed office park, the parcel is almost certainly encumbered by existing utility easements (power, water, sewer, telecommunications). A title report and ALTA survey are required to identify the location and restrictions of these easements, as they will constrain the final site layout. Access easements from the public right-of-way to the parcel boundary should be confirmed but are expected to be in place.

2. Environmental Constraints

FEMA Flood Zone: The FEMA flood zone designation is currently Unknown. This is a critical data gap. Any portion of the site located within a 100-year floodplain (e.g., Zone A or AE) would introduce significant design challenges and costs associated with elevating all equipment above the Base Flood Elevation (BFE), or could render the site undevelopable. This must be investigated immediately via FEMA's Map Service Center.

Wetlands: The presence of jurisdictional wetlands is Unknown. A desktop screening using the National Wetlands Inventory (NWI) is a priority. If potential wetlands are identified, a formal wetland delineation will be necessary. The presence of wetlands would trigger setback requirements and could reduce the buildable area, impacting project feasibility.

Critical Habitat / Endangered Species

📸 Satellite Inspection

Satellite Close-up
Close-up (Zoom 17)
Satellite Wide
Context View (Zoom 14)
Terrain Map
Terrain / Roads

📝 Add Note

📋 Note History

No notes yet. Add the first note above.