⚡ 1480 RENAISSANCE DR

Cook County, IL — Intake Report
📍 42.0336601, -87.8646427 📐 35.02 acres 🏷️ APN: 9221100050000 🔌 6fb54528-966c-4764-bda6-1e20dc045eb5 📅 Generated July 02, 2026 07:23 AM 🆔 IL001590
BESS Score: /10 Buildable: ac Nearest Sub: - (-) Zoning: Commercial (Office) - Office Bldg (Multi-Story)
🗺️ Map
📐 Site Layout
📋 Overview
🤖 AI Analysis
📝 Notes

🔍 Site Diligence

Complete these items. Changes save automatically.
AHJ Confirmed
Verify governing jurisdiction via municipality overlay
Zoning Verified
Confirm BESS-compatible zoning or CUP/SUP pathway
Flood/Wetlands Clear
FEMA Zone X or buildable area avoids flood/wetlands
Site Access Confirmed
Road access, easements, equipment delivery route
Substation Feasibility
Nearest substation capacity and voltage suitable
Setback Analysis
Buildable acreage accounts for required setbacks
Environmental Clear
No endangered species, conservation areas, brownfield issues
Title Clear
No liens, encumbrances, or easement conflicts

📝 Diligence Fields

🏠 Property Details

IMPERIAL REALTY CO -
35.02
9221100050000
Commercial (Office) - Office Bldg (Multi-Story) (-)
Battery Energy Storage
Cook County
17031

⚡ Infrastructure

6fb54528-966c-4764-bda6-1e20dc045eb5
-
-
- kV
138kV at 1.5 mi (COMMONWEALTH EDISON CO)
633 ft
Not prime farmland
🔴 941 structures within 0.5 mi (setback/opposition risk)
Public

🌊 Environmental

Loading...
Loading...
N/A (non-MD)
None within ~3 miles
None within ~2 miles
None
None
1 site(s) within ~2 mi

💰 IRA/ITC Adders

No
Yes — Fossil Fuel Employment (FFE Area)
No

🏛️ Jurisdiction

Park Ridge
City
Park Ridge

📊 Assessment

/10

🤖 AI Site Assessment — Gemini Deep Research

MEMORANDUM

TO: Sunland America Corp. Development Committee

FROM: Senior BESS Site Evaluation Analyst

DATE: October 26, 2023

SUBJECT: Comprehensive Site Diligence Analysis for "Project Renaissance"

PROPERTY: 1480 RENAISSANCE DR, Park Ridge, Cook County, IL (APN: 09221100050000)

FINAL RECOMMENDATION: MAYBE

This report provides a comprehensive initial diligence analysis for the subject property as a potential site for a distribution-scale (≤5MW) Battery Energy Storage System (BESS). While the site benefits from a valuable 10% ITC adder and excellent location, critical data gaps regarding grid interconnection and environmental constraints present substantial go/no-go risks. The project is not viable without immediate investigation into these key unknowns.

1. Site Access & Topography

Road Access: The property has excellent access. It is located in a well-developed commercial office park with direct frontage on Renaissance Drive, a paved, public road. The site is situated less than a mile from Interstate 294, providing a direct and efficient route for equipment delivery from major transportation corridors.

Terrain & Equipment Feasibility: Based on aerial imagery and the general geography of the Chicago metropolitan area, the site's topography is presumed to be flat. This is highly advantageous, as it will minimize civil engineering and grading costs, which can be substantial on sloped sites. The existing commercial-grade road infrastructure appears fully capable of supporting heavy equipment delivery, including semi-trucks carrying battery containers, pad-mount transformers, and construction cranes. No immediate obstacles like low-clearance bridges or restrictive turning radii are apparent on the primary access routes.

Easement Concerns: As a developed commercial parcel, the site is almost certain to be encumbered by existing utility easements (e.g., power, water, sewer, telecommunications). A full ALTA survey and title report are required to identify the location and restrictions of these easements, as they will directly impact the usable area for BESS equipment placement. Access easements are not anticipated to be a concern due to the direct public road frontage. A significant discrepancy exists between the listed "Total Acres" (35.02) and "Parcel Acres" from Regrid (2.97). We are proceeding under the assumption the 2.97-acre parcel is the target; this must be confirmed immediately via a title search, as it fundamentally impacts project scale and viability.

2. Environmental Constraints

FEMA Flood Zone & Wetlands: The status for both flood zone and wetlands is currently Unknown. These represent critical, potentially fatal flaws. An immediate review of FEMA's Flood Insurance Rate Maps (FIRMs) is required. If the site is located within a 100-year floodplain (e.g., Zone A or AE), development costs will increase significantly due to the need for elevated foundations, and permitting may be impossible. Similarly, a desktop screening using the National Wetlands Inventory (NWI) is a mandatory first step. The presence of jurisdictional wetlands would trigger significant setbacks and require a formal wetland delineation, potentially rendering the buildable area too small for the project.

Habitat & Protected Species: The data indicates no critical habitat or protected areas on or near the site, which is a positive finding consistent with a developed suburban location. This significantly lowers the risk of project delays or mitigation requirements from the U.S. Fish and Wildlife Service. A formal desktop review using the USFWS IPaC tool is still recommended as a standard diligence step.

Contamination Risk: The property is not listed as a brownfield, but one Superfund site is noted within a two-mile radius. This proximity necessitates a Phase I Environmental Site Assessment (ESA) to ensure no soil or groundwater contamination has migrated to

📸 Satellite Inspection

Satellite Close-up
Close-up (Zoom 17)
Satellite Wide
Context View (Zoom 14)
Terrain Map
Terrain / Roads

📝 Add Note

📋 Note History

No notes yet. Add the first note above.