⚡ 1480 RENAISSANCE DR

Cook County, IL — Intake Report
📍 42.0336601, -87.8646427 📐 35.02 acres 🏷️ APN: 9221100050000 🔌 6fb54528-966c-4764-bda6-1e20dc045eb5 📅 Generated June 30, 2026 03:19 AM 🆔 IL001590
BESS Score: /10 Buildable: ac Nearest Sub: - (-) Zoning: Commercial (Office) - Office Bldg (Multi-Story)
🗺️ Map
📐 Site Layout
📋 Overview
🤖 AI Analysis
📝 Notes

🔍 Site Diligence

Complete these items. Changes save automatically.
AHJ Confirmed
Verify governing jurisdiction via municipality overlay
Zoning Verified
Confirm BESS-compatible zoning or CUP/SUP pathway
Flood/Wetlands Clear
FEMA Zone X or buildable area avoids flood/wetlands
Site Access Confirmed
Road access, easements, equipment delivery route
Substation Feasibility
Nearest substation capacity and voltage suitable
Setback Analysis
Buildable acreage accounts for required setbacks
Environmental Clear
No endangered species, conservation areas, brownfield issues
Title Clear
No liens, encumbrances, or easement conflicts

📝 Diligence Fields

🏠 Property Details

IMPERIAL REALTY CO -
35.02
9221100050000
Commercial (Office) - Office Bldg (Multi-Story) (-)
Battery Energy Storage
Cook County
17031

⚡ Infrastructure

6fb54528-966c-4764-bda6-1e20dc045eb5
-
-
- kV
138kV at 1.5 mi (COMMONWEALTH EDISON CO)
633 ft
Not prime farmland
🔴 941 structures within 0.5 mi (setback/opposition risk)
Public

🌊 Environmental

Loading...
Loading...
N/A (non-MD)
None within ~3 miles
None within ~2 miles
None
None
1 site(s) within ~2 mi

💰 IRA/ITC Adders

No
Yes — Fossil Fuel Employment (FFE Area)
No

🏛️ Jurisdiction

Park Ridge
City
Park Ridge

📊 Assessment

/10

🤖 AI Site Assessment — Gemini Deep Research

MEMORANDUM

TO: Sunland America Corp. Development Committee

FROM: Senior BESS Site Evaluation Analyst

DATE: October 26, 2023

SUBJECT: Comprehensive Site Diligence Analysis for APN 09221100050000 (1480 Renaissance Dr, Park Ridge, IL)


This report provides a comprehensive due diligence analysis for the property located at 1480 Renaissance Drive in Park Ridge, Cook County, Illinois. The analysis evaluates the site's suitability for a distribution-scale (≤5MW) Battery Energy Storage System (BESS) project based on key development criteria. The site presents a compelling financial incentive through its Energy Community status but faces significant uncertainty and risk in grid interconnection and local permitting.

1. Site Access & Topography

  • Road Access & Feasibility: The site benefits from Public road access via Renaissance Drive, located within a well-developed commercial office park immediately adjacent to the I-294 Tollway. The existing road infrastructure appears robust and suitable for standard construction traffic. However, a detailed logistics review is required to confirm that turning radii can accommodate oversized vehicles for delivering large transformers and battery containers.
  • Topography: As is typical for the Chicago metropolitan area, the site is expected to be exceptionally flat. This is a significant advantage, as it will likely eliminate the need for extensive civil work and grading, thereby reducing site preparation costs and timelines.
  • Heavy Equipment Access: Access for heavy equipment, including cranes for setting transformers and containers, appears feasible. A site visit is necessary to verify the absence of overhead utility lines or other vertical obstructions along the planned delivery route from the main thoroughfare to the project footprint.
  • Easement Concerns: A significant data discrepancy exists regarding parcel size (35.02 acres vs. 2.97 acres from different data sources). Assuming the smaller 2.97-acre size is correct, the buildable area could be severely constrained by existing utility, access, or drainage easements common in established commercial parks. Action Item: A title report and ALTA survey are critical to confirm the legal parcel boundaries and identify any encumbrances that would impact the BESS layout.

2. Environmental Constraints

  • FEMA Flood Zone: The FEMA flood zone designation is currently Unknown. This is a critical and potentially fatal flaw. Any designation within a 100-year floodplain (e.g., Zone A, AE) would introduce substantial design complexity, cost (raising all equipment above the Base Flood Elevation), or render the site undevelopable. Action Item: An immediate desktop review using the FEMA Map Service Center is required.
  • Wetlands: The presence of jurisdictional wetlands is Unknown. Given the developed nature of the area, the risk may be low, but cannot be dismissed. A desktop screening using the National Wetlands Inventory (NWI) is the first step. If potential wetlands are identified, a formal delineation will be necessary, which could trigger significant setbacks and reduce the buildable area.
  • Critical Habitat / Species: The data indicates no critical habitats or

📸 Satellite Inspection

Satellite Close-up
Close-up (Zoom 17)
Satellite Wide
Context View (Zoom 14)
Terrain Map
Terrain / Roads

📝 Add Note

📋 Note History

No notes yet. Add the first note above.